How to make a pollen reference collection, step by step
A reference slide is only as good as the plant it came from and the way it was made. This guide takes you from choosing taxa to a catalogued, photographed, citable collection, with a labelling template you can copy.
To make a pollen reference collection, take pollen from plants whose identity is verified (a herbarium voucher, a botanic-garden accession or a field identification by a named person), process it with the same chemistry you use on your samples, and mount it in the same medium. Then label every slide with taxon, source and voucher, collector, date, locality, preparation and mountant, and photograph and measure the grains. Catalogue each slide, keep the leftover residue, and store slides flat.
The reason for all this care is simple. As Chambers et al. (2011) put it, “for precise and accurate pollen identification there is no adequate substitute for a pollen reference collection”. Atlases and databases help, but the final check is a slide of known origin, prepared like your unknown, under your own microscope.
The method in ten steps
- Define the scope. List the taxa you expect in your samples, by region and project, and rank them by how often they occur and how hard they are to separate.
- Choose a verified source for each taxon: herbarium voucher, botanic-garden accession or documented field identification.
- Get permission from the herbarium or garden, and any collecting permits you need.
- Collect ripe anthers or flowers into a clean, labelled paper packet, one specimen per packet.
- Record provenance at the moment of collection: who identified the plant, the voucher or accession number, locality, date and collector.
- Process the pollen with your sample protocol (for most Quaternary labs, acetolysis), leaving out mineral-removal steps that are irrelevant to clean anther material.
- Mount in the same medium as your samples, at a density that leaves grains separate and turnable.
- Label and catalogue each slide with a unique code, and keep the residue vial with the same code.
- Photograph and measure grains with a calibrated camera or graticule, including focus series.
- Store and maintain: slides flat, in a slide cabinet, checked periodically; digitise and back up the images.
The sections below explain each step and the decisions behind it.
Why your own collection still matters
Online databases now hold tens of thousands of pollen images. PalDat, for example, reports 37,579 pictures covering 4,683 species (figures from its home page, updated 22 October 2026), and the Australasian Pollen and Spore Atlas says it holds details on “over 15,000 species”. So why spend time making slides?
- Like must be compared with like. Preparation and mountant change how a grain looks and how big it is. Chambers et al. (2011) state that reference material “should be prepared, stained (or not), extracted and mounted according to the preparation technique for subfossil pollen used in the laboratory”. An image of a fresh, hydrated grain is not directly comparable with an acetolysed grain in silicone oil. PalDat itself notes that its SEM pictures usually show the hydrated state of recent pollen, while its light-microscope pictures usually show acetolysed grains.
- A slide can be turned and focused. Pollen is three-dimensional. A slide lets you roll a grain to see the pole, then the equator, and focus through the wall; a photograph shows only what its author chose.
- Your flora is local. Online collections are uneven. The plants that matter in your region, or the confusing pairs in your project, may be missing or represented by a single specimen.
- Accuracy matters more than precision. Chambers et al. stress that incorrect identifications “are potentially far more misleading” than imprecise ones. Reference slides are how you test a doubtful identification honestly.
Plan: what to collect first
You do not need everything at once. Chambers et al. (2011) note that bogs are species-poor, so a rudimentary collection of bog taxa needs few slides; fens are richer; and a comprehensive collection “requires at least several hundred or, in some species-rich regions, potentially thousands of typeslides”. Start with the taxa that most affect your results.
| Project type | Collect first | Why |
|---|---|---|
| Peat or lake core, Holocene | Regional trees and shrubs, main herbs of the pollen sum, local mire plants | They dominate the sum and the diagram’s interpretation |
| Honey (melissopalynology) | Main nectar plants of the region, plus look-alikes of the unifloral types you certify | Unifloral claims depend on separating key types; see honey pollen analysis |
| Archaeology | Crops, crop weeds, pasture indicators and the local woodland flora | Interpretation rests on cultural indicators |
| Forensic | Plants at and around the scenes and the common regional background | Comparisons are site-specific; see forensic palynology |
| Aerobiology and allergy | Wind-pollinated trees, grasses and weeds of the monitoring area | These dominate air samples; see how pollen counts are measured |
Inside each list, give priority to difficult pairs, the taxa your key separates on size or fine ornamentation. These are where your own measured reference series pays off most.
Sourcing verified material
The value of a reference slide depends entirely on the identification of the plant it came from. The Global Pollen Project (GPP), which hosts digital reference collections, distinguishes three kinds of identification for reference material: direct (taken from an identified plant), morphological (identified from the pollen’s morphology only) and environmental (from a modern environmental sample, identified morphologically). For a reference collection, aim for direct identification. GPP records three ways the plant itself was identified (GPP digitisation guide):
| Source | What to record | Strengths | Watch out for |
|---|---|---|---|
| Herbarium voucher | Herbarium code and the herbarium’s ID for the voucher | Identification checked by professionals; permanent, citable specimen | Needs permission for destructive sampling; old sheets may have few mature anthers |
| Living plant in a botanic garden | Garden code and the garden’s ID for the plant | Fresh, abundant pollen; plant can be revisited | Cultivated plants and cultivars may not match wild populations; check the accession’s identification |
| Field identification | Name of the person who identified the plant | Local wild populations; sample several individuals | Only as reliable as the identifier: press a voucher specimen and photograph the plant |
| Commercial pollen | Supplier, batch and stated species | Convenient for some taxa | Chambers et al. note it is sold mainly by allergen suppliers and “price varies enormously”; provenance is weaker than a voucher |
Herbarium codes are standardised. Index Herbariorum, maintained by the New York Botanical Garden, is the worldwide index of herbaria and their codes; use the code it gives so that anyone can trace the voucher.
Permissions and permits. Taking anthers from herbarium sheets is destructive sampling, so ask the curator first and follow the herbarium’s sampling rules. Botanic gardens have their own collecting policies. Wild collection may need landowner permission, and protected species or areas need permits. If material crosses borders, check the access and benefit-sharing rules of the country of origin, which may implement the Nagoya Protocol on Access and Benefit-sharing. When in doubt, ask the institution’s collections or legal office before you collect.
Collecting pollen without contaminating it
Contamination is the silent failure of reference collections: a single foreign grain on a reference slide can teach you the wrong morphology. Practical rules:
- Take ripe material. Choose flowers whose anthers have just opened or are about to, so the pollen is mature. On herbarium sheets, pick buds or flowers with intact anthers rather than scraping loose pollen from the sheet, which may have come from neighbouring specimens.
- One specimen, one packet. Put each sample in its own paper packet or envelope, labelled before you start. Paper lets material dry; sealed plastic can trap moisture.
- Clean tools between specimens. Wipe or flame forceps and wash hands or change gloves between plants.
- Sample more than one individual where you can, especially in the field, and keep them separately labelled if you want to see variation.
- Write the provenance immediately: taxon, identifier, voucher or accession number, locality, date and your name. Anything you plan to add later will be forgotten.
Processing: same chemistry as your samples
This is the rule that matters most. If your samples are acetolysed, your reference pollen must be acetolysed; if your honey slides are untreated, prepare untreated reference slides as well (and acetolysed ones too if you sometimes acetolyse). Chambers et al. (2011) add one practical exception: reference material is processed like the samples “but usually with the omission of chemical stages for removing mineral material, as this may alter grain size”. Clean anther material has no silt to remove.
A typical sequence for a Quaternary lab looks like this. Follow your own laboratory’s protocol and risk assessment; our guide to acetolysis and slide preparation explains what each step does and why the reagents are hazardous.
- Free the pollen from the anthers by crushing them in water or acetic acid in a centrifuge tube; remove plant debris with a fine sieve.
- Dehydrate in acetic acid, then acetolyse with the 9:1 mixture of acetic anhydride and sulphuric acid in a heated water bath. The Amsterdam peat protocol reproduced by Chambers et al. heats at 100 °C for about 10 minutes; reference material should get the same treatment as your samples.
- Stop the reaction (by cooling, or by adding acetic acid as in Jones 2014), centrifuge, then wash with water until the supernatant is clear.
- Stain if your samples are stained: Jones (2014) describes safranin O as the “preferred” stain for most palynological uses.
- Dehydrate and transfer to the mountant (alcohol series for silicone oil, water or glycerine for glycerine jelly).
Two habits help later. Keep part of each residue in a labelled vial, so you can make a new slide if one is damaged. And record exactly what you did: the GPP metadata form asks for the “most destructive procedure” applied (fresh grains, acetolysis or HF) and the mounting medium, because these determine what a grain looks like.
Mounting media compared
The two standard mountants are glycerine jelly and silicone oil. Chambers et al. (2011) describe “robust debate among practitioners” over which is best and note that “each has its merits”. For a reference collection the overriding rule is to use the same medium as your sample slides.
| Glycerine jelly | Silicone oil (silicone fluid) | |
|---|---|---|
| Preparation | Simple: residue in water or glycerine, melted jelly, coverslip | Longer: residue must be fully dehydrated (alcohol, then tert-butyl alcohol or toluene) before mixing with the oil |
| Effect on grain size | Can change size; values are comparable only with slides made the same way | Chambers et al.: “not altering pollen grain size overmuch”. Andersen (1960) introduced it for this reason |
| Turning grains | Grains fixed once the jelly sets | Grains can be rolled by nudging the coverslip; viscosity controls how easily |
| Drying and sealing | Coverslip usually sealed (nail varnish or VALAP, as described by Jones 2014) | Practically non-volatile: slides “never dry out and do not need sealing”, though many labs seal to keep oil off stages and lenses |
| Viscosity choice | Not applicable | Chambers et al. report 2,000 cs as usual for samples, with some labs using 12,500 cs for type slides; a different viscosity changes how freely grains turn |
| Typical use | Honey analysis (harmonised method), many teaching collections | Many Quaternary and peat laboratories |
For grain-size work, Chambers et al. recommend that the mountant of sample slides “should match that used for the laboratory’s pollen reference collection”. If you inherit a collection mounted differently, label that clearly and treat size comparisons with caution.
Labelling and cataloguing template
A reference slide without its data is a pretty picture, not evidence. Write a short code on the slide itself (diamond pen or permanent label) and keep the full record in a catalogue. The template below covers what you need for your own use and the fields the Global Pollen Project asks for if you later publish the collection online.
SLIDE CODE: [collection]-[year]-[running number] e.g. ABC-2026-0147
TAXON: [family] [genus] [species] [authority]
NAME CHECKED IN: [taxonomic backbone / flora used]
IDENTIFICATION: direct / morphological / environmental
SOURCE: herbarium voucher / botanic garden / field
VOUCHER OR ACCESSION: [herbarium code from Index Herbariorum + voucher ID]
or [garden code + accession ID]
IDENTIFIED BY: [full name] (required for field identifications)
COLLECTED BY: [full name] DATE: [yyyy-mm-dd]
LOCALITY: [country, region, locality; coordinates if known]
PREPARED BY: [full name] PREP DATE: [yyyy]
PROCESSING: fresh / acetolysis ([time, temperature]) / HF / other
STAIN: none / safranin O / basic fuchsin
MOUNTANT: glycerine jelly / silicone oil ([viscosity, cs])
SEALANT: none / nail varnish / VALAP / other
RESIDUE VIAL: [same code] LOCATION: [cabinet, tray]
MEASUREMENTS: [axis] n = [ ], mean [ ] µm, range [ ]–[ ] µm, objective [ ]
IMAGES: [file names / online record]
NOTES: [condition, contamination, anomalies]Keep the catalogue in a spreadsheet or database with one row per slide and the same columns. Use full names for people (GPP tracks who identified, collected, prepared and digitised each slide to credit contributions), and always use a valid scientific name checked against a named taxonomic source.
Imaging, measuring and digitising
Photographing your reference grains turns a cabinet of slides into something you can search, share and use at the microscope. Three things make the images scientifically useful.
1. Calibrated images
Every image needs a scale. The GPP requires all uploaded images to be calibrated to micrometres. With a camera fixed to the microscope, you calibrate each objective once from a photograph of a stage micrometer or scale bar; for ad-hoc photos, including phone pictures down the eyepiece, a “click-click” calibration against a known distance in the image is accepted. Our microscope guide explains how to calibrate an eyepiece graticule for measuring by eye.
2. Focus series
At high magnification you see one thin optical plane at a time, so one photograph cannot show the whole grain. Photograph the same grain at several focal planes (surface, mid-wall, optical section) and keep the stack. The GPP turns such stacks into “focusable images, just like using a microscope”. Photograph standard views too: polar and equatorial, plus close-ups of apertures and ornamentation at the highest magnification you have.
3. Measurements with their context
Measure several well-preserved grains per slide along the axes your key uses, and record the number of grains measured, the mean and range, the objective, the preparation and the mountant. A single measurement says little about a taxon’s variation, and a measurement without its preparation details cannot be compared with anyone else’s.
Publishing online
If you publish through the Global Pollen Project, a slide becomes “fully digitised” when its name is valid in the GPP taxonomic backbone, the identification is confirmed, and at least one image is uploaded. Collections go through a short content review; the GPP notes that publication is irreversible, with corrections made by issuing a new version, which keeps cited versions available. This versioning is useful if your thesis or paper cites the reference collection.
Storage and lifespan of slides
Reference slides last a long time, but not forever. Chambers et al. (2011) give a rare long-term observation: type slides made at Queen’s University Belfast in silicone fluid and sealed with “knotting” (a sealer used on wood knots) “were free of blemishes for some 25 years”, but later developed crystalline structures that made them unusable, while type slides sealed with varnish “deteriorated much earlier”.
- Store flat in slide cabinets or trays, especially silicone mounts, so that the mountant does not creep.
- Keep residues. A labelled vial of residue lets you remake a slide when one deteriorates.
- Check a sample of slides periodically and note their condition in the catalogue; remake those that show crystals, drying or bubbles.
- Back up images and the catalogue in at least two places. A digitised collection survives broken slides; an undocumented one does not survive the person who made it.
Existing collections and atlases you can use
Your own slides are for confirmation. For browsing candidates and checking descriptions, use the published resources. Chambers et al. (2011) point to Hooghiemstra & van Geel (1998) for a world list of Quaternary pollen and spore atlases.
| Resource | What it offers | Use it for |
|---|---|---|
| PalDat | Palynological database of recent pollen with LM and SEM images and standard terminology | Checking morphology and terms; LM images are usually of acetolysed grains |
| Australasian Pollen and Spore Atlas (APSA) | Online atlas of the Australasian region, over 15,000 species listed | Southern hemisphere and Pacific floras |
| Global Pollen Project | Digitised reference collections with calibrated, focusable images; tools to digitise your own | Comparing candidates; publishing your own collection |
| Northwest European Pollen Flora (from Punt & Clarke 1976), Reille (1992), Beug (2004) | Printed photographic atlases and keys | Europe and North Africa; systematic identification |
| Faegri & Iversen (1989); Moore, Webb & Collinson (1991) | Textbooks with identification keys | North-west Europe; see our books page |
More databases, societies and laboratories are listed in our palynology directory, and terms are defined in the glossary.
Common mistakes
- Unverified plants. A garden plant labelled by a nursery, or a field plant nobody checked, gives a slide with a confident label and an uncertain identity.
- Different preparation from the samples. Fresh reference grains compared with acetolysed fossil grains, or glycerine jelly versus silicone oil, will mislead you on size and appearance.
- Scraping loose pollen from herbarium sheets. It may come from neighbouring specimens; take anthers from the specimen itself, with permission.
- Overloaded mounts. Too many grains overlap and cannot be turned; too few make photography slow. Make a test slide and adjust.
- Incomplete labels. No voucher, no preparation, no mountant: the slide cannot be audited.
- One specimen per taxon for size-critical types. Variation within a species needs more than one plant to see.
- No backup of images or catalogue. Slides break and people move on.
Frequently asked questions
- What is a pollen reference collection?
- A set of microscope slides of pollen taken from plants whose identity is known, prepared and labelled so that unknown grains can be compared with them. Many labs also keep the processed residues and digital images of each slide.
- How many slides does a reference collection need?
- It depends on the flora. Chambers et al. (2011) note that a rudimentary collection for species-poor bogs needs few slides, while a comprehensive collection needs at least several hundred and, in species-rich regions, potentially thousands. Start with the taxa that dominate or complicate your own samples.
- Can I use herbarium specimens to make reference slides?
- Yes, with the herbarium’s permission, because removing anthers is destructive sampling. Record the herbarium code and the voucher ID so that the identification can be traced.
- Should reference pollen be acetolysed?
- Prepare it the same way as the samples you will compare it with. If your samples are acetolysed, acetolyse the reference pollen too, usually leaving out mineral-removal steps such as HF, which clean anther material does not need and which may alter grain size.
- Glycerine jelly or silicone oil for reference slides?
- Use the mountant you use for your samples. Silicone oil changes grain size less and lets grains be turned; glycerine jelly is simpler and is the standard in the harmonised honey method.
- How long do reference slides last?
- Decades, if stored well, but not indefinitely. Chambers et al. (2011) report silicone-fluid type slides that stayed free of blemishes for about 25 years before developing crystals, while varnish-sealed slides deteriorated earlier. Keep residues so slides can be remade.
- Can I buy pollen reference slides instead?
- Some ready-made slides and commercial pollen are available, but they may not match your preparation, mountant or local flora, and their provenance is usually weaker than a voucher-based slide of your own.
- How do I share my reference collection online?
- Digitise it with calibrated images and full metadata and publish it through a platform such as the Global Pollen Project, which reviews collections, credits contributors and versions each release so that cited versions stay available.
Sources
- Chambers, F.M., van Geel, B. & van der Linden, M. (2011). Considerations for the preparation of peat samples for palynology, and for the counting of pollen and non-pollen palynomorphs. Mires and Peat 7, art. 11 (section 2D on silicone fluid; sections 3.2–3.5 on atlases, keys, type-slide collections and accuracy).
- Global Pollen Project. Digitising your reference material (identification types, metadata, calibration, publication and versioning).
- Jones, G.D. (2014). Pollen analyses for pollination research, acetolysis. Journal of Pollination Ecology 13: 203–217.
- Andersen, S.T. (1960). Silicone oil as a mounting medium for pollen grains. Danmarks Geologiske Undersøgelse IV. Række 4: 1–24.
- PalDat (2020). Illustrated Pollen Terms; PalDat home page (database statistics, accessed 31 October 2026).
- Australasian Pollen and Spore Atlas, Australian National University (accessed 31 October 2026).
- New York Botanical Garden. Index Herbariorum.
- Convention on Biological Diversity. The Nagoya Protocol on Access and Benefit-sharing.
The processing outline is for orientation only and is not a laboratory protocol: acetolysis and HF are hazardous and must follow your institution’s procedures and risk assessment. Database statistics change; figures are as displayed on the date checked.